DSP-VIP-PM DSP-VIP-PM/Voltage-Current based power type
DSP-VIP-PM/Voltage-Current based power type
Main Feature
- Panel Flush Mounting Type:Converter,Display meter,Communication Module
- Protection:Over/Under voltage,Over/Under Load(KW)/Current,Ground fault,Over Temp,Short circuit,Shock,Locked Rotor,Phase Loss,Reverse Phase
- Indication:KW,KWH,A, V,GR,TEMP,PF(CosΘ),working time,Number of MC ON-OFF
- Additional Function:RS 422/485, Y-D,R-F,Reactor starting,Shut down delay timer & Delay on-make timer
- Pre-maintenance:Able to preset alarm point/O,U curr.GF,Temp,Shock(Stall),MOTOR working time, short circuit in Instant (within 30msec)
- Particulary Useful for process control and pre-maintenance as presetting various alarm factor
Easy Handling
- to realize convenient & various data input
- Display Meter
- Loader
- Note Book PC
- Main/Sub/Cab Menu :three seperated menu according to usage and data input frequency
- Main menu :Data input frequency is rather higher
- Sub menu : ratherly common application for all kind of motor
- Cab menu(calibration menu):adjustable for indicating value within narrow range(+,- 12.7%)/this menu is appeared when "SET" key is pressed for 5 sec or more and disappeared right after pressing again
- Back lit display:easy handling in dark space of the panel
- To indicate a necessary in every 3 sec
- basic factor circulating indication:V,I,KW,GR/"OFF" must be set in "rota" mode
- Basic Factor + PF,temp,KWH,AWT(Accumulated working Time)/"ON" must be set in "rota" mode/Possible to fix one of circulated factor or to release:one touch for "CLR" key
- Possible to check presetting value during operation / "SET" & "MODE" key / Mode and value is shown alternatively / return to operating state without input for 10 sec or pressing "Mode" key/ not possible to preset value
- To show load factor(actual/setting)/65%~100%,Round type
- Duplex Alarm : Higher Alarm,Lower Alarm to OC
- To secure a safety: Password input for setting a data
- ON-OFF switch/DSP-VIP-PM:to save wiring and labor inside panel
- Convenient installation:65 Phi circle or rectangular hole/DSP-VIP-PM:Display Meter
- To indicate tripped number of main contactor:contributing to check a replacing term and effective maintenance
- To call initialized factory setting value:pressing test button before power-on and keeping a press for 3 sec after power-on.
- To keep a stable operation under frequency variation of inverter:10 Hz~400Hz
Multi-complexed Function
- Power type protection relay based on Voltage and Current
- to indicate RMS value/Voltage,Current:RMS chip adopted in every input/to contribute to check an exact condition of motor
- Provides actual meter function:V,I,KW,PF,KWH,temp
- Voltage Select:110V/220V/380V/440V
- Current Meter with CT:0.5A~3600A(Auto range for dcimal point)
- KW Meter:0.01~66535 KW(Auto range for dcimal point)
- Power factor Meter:+,-,0%~100%
- Meter:0.1KWH~66535 KWH
- Temperature Meter:0 ~150 degree C
- Auto ramge:to indicate decimal point in conjunction with "K/Test" LED in Loader and DM
- To cover a wide current range
- 70 Type : 0.2 ~70A/ 0.2A~6A with an external CT(“5t” must be selected in “cto”mode)
- With external CT:0.5A ~ 3000A
- To realize Short,Ground fault protection by instant time:within 0.05sec
- To be acceptable for various rating of ZCT:200/1.5mA or 200/100mV,selectable in DIP SW
- Temperature protection/motor winding:sensed by PT100
- Not posible to start under keeping over temperature than presetted value
- if PT100 is not connected before starting, alarm message is coming out and not allow to start.
- Above all condition can be clear as making temperature mode disable.
- various and multiple output of Main and Aux internal relay
- Main / 1a-1b(95-96,97-98) :energized with output of internal relay,C-M-D-Y,at same time
- AUX : 1C X 1 / 07-08-10 :acts same as main trip or one of Shoc/Ec/AL/Uc/AL/Temp/Ec-tE selected in "Au-o" mode
- X1 / 27-28-30:trip for voltage protection ,but possible to change into "ALLc"(lower level alarm) in "Line" mode
- Y-Delta Starting Timer: not neccessary for additional circuit ,to save labor and space
- to memoize latest number of 8 tripped cause:to contribute analysing trouble cause and keeping a data after power-off
- main contactor Auto Close:in case a line power is "ON" again within a presetting time(SDDT) after a line power is "OFF" during a normal operation,main contactor is closed automatically after another presetting time(DOMT)
- Shut Down delay Time:1~5 sec/Adjustable
- delay On make Time:0(Instant)~25sec/Adjustable 5 sec unit
- Expression in mode:eg/2-3:in case power is "on" within 2 sec after power-off,motor restarts after 15 sec(3 is matched with 15 sec) from instant of power-on.
- Self-diagonostics:main trip output is tripped after counting down o-time of definite T-I or a time of 550% to "OC" Inverse T-I
Remote Control through RS 485/422, Ethernet Communication
- Remote Control through RS 485/422 Digital Communicatio
- Basically 4~20mA Output:max curremnt of 3 phase
- To realize effective system for digital communication:posible to combine a module simply if neccessary
- To response for RS 485/422, Modbus
- CM-44E Model : Ethernet, Modbus TCP
- To select one of RS485 and 422:Simply selectable in DIP SW inside communication module
- To put easily termination resistance in extreme end unit:Simply selectable in DIP SW inside communication module
- To monitor and input a data in the field:Note PC converter<>in DSP
Catalog
- CATEGORY
- SUBJECT
- DOWNLOAD
- MODIFY DATE
- Comprehensive Catalog
- 2021 카탈로그
- 2021 카다로그.pdf
- 2021-06-18
Cad
- CATEGORY
- SUBJECT
- DOWNLOAD
- MODIFY DATE
- DSP-VIP-PL/PM 치수도
- DSP-VIP-PL_PM 치수도.pdf
- 2020-11-18
- DSP-VIP-PL/PM 결선도
- DSP-VIP-PL_PM 결선도.pdf
- 2020-11-18
Ordercode
Other Series
-
DSP-CTM-N -
DSP-VIP-PM -
DSP-VIP-PL -
DSP-M200/M200-C/M200-VA -
DSP-VIP-RTM -
DSP-VIP-5SM -
DSP-VIP-5CM -
DSP-PCTM -
DSP-PCM -
DSP-CCTM -
DSP-CCM-PT -
DSP-AOM -
DSP-AOM-N -
DSP-AOL-RG -
DSP-MWR-S -
DSP-CM44 -
DSP-3CT -
DSP-ZCT -
WKS-1340SQH -
DSP-UVR -
DSP-VPR -
DSP-SDTR-P:Socket-Pin Type -
DSP-DVR -
DSP-DCR -
DSP-DGFR -
DSP-POL-EC -
DSP-3ESS -
DSP-UCR -
DSP-3SD, 3SD-RG -
WKS-3270HFAC -
WKS-1210G2H04T -
WKS-1220G2H04T -
WKS-1230G2H04T -
WKS-1240G2H04T -
WKS-3340H04 -
WKS-1340G2H04T -
WKS-1330G2H04T -
WKS-1320G2H04T -
WKS-0220MAB -
WKS-3340HFAC -
WKS-3340FRMN -
WKS-3325FRMP -
WKS-3340FRMP -
WKS-1325MAC -
WKS-3325FRMN -
WKS-3325MAC -
WKS-1325M04 -
WKS-3340MAC -
WKS-1340MAC -
WKS-3325M04 -
WKS-3370HFAC -
WKS-3340M04 -
WKS-1340M04 -
WKS-3325H04 -
WKS-1370SQHAC -
WKS-3340HAC -
WKS-33130HF04T -
WKS-3370HAC -
WKS-3370HF04T -
WKS-1370SQH -
WKS-1225SQHAC -
WKS-1240SQHAC -
DSP-CM44E -
WKS-1320G2HR -
WKS-1320G2HA -
WKS-1220G2HD -
WKS-1220G2HR -
DSP-AOM-RG -
WKS-1203PBZL -
WKS-0203PBZL -
WKS-1320G2HD -
WKS-1220G2HA -
WKS-1350G2H04T -
WKS-1310G2H04T -
WKS-1250G2H04T -
WKS-3240HFAC -
WKS-3340HHAC -
WKS-3325HHAC -
WKS-3240HHAC -
WKS-3225HHAC -
WKS-33110HF04T -
WKS-3340HF04T -
WKS-3270HF04T -
WKS-3240HF04T -
WKS-3340HH04 -
WKS-3325HH04 -
WKS-3240HH04 -
WKS-3225HH04 -
WKS-3325HAC -
WKS-3270HAC -
WKS-3240HAC -
WKS-3225HAC -
WKS-3370H04 -
WKS-3270H04 -
WKS-3240H04 -
WKS-3225H04 -
WKS-1340SQHAC -
WKS-1325SQHAC -
WKS-1270SQHAC -
DSP-IR -
DSP-IRM -
DSP-DGFR-M -
DSP-DCR-M -
DSP-DVR-M -
DSP-VPFR -
DSP-OVR -
DSP-SP -
DSP-2SD -
DSP-AOL -
DSP-CCM-N -
DSP-CCL-PT -
DSP-CCM-ET -
DSP-CCM-E,CCM-ES -
DSP-CSM -
DSP-CSL -
DSP-CCM -
DSP-CCL -
DSP-CTM -
DSP-CTL -
DSP-COM -
DSP-COL -
DSP-PCL -
DSP-PTM -
DSP-PTL -
DSP-POM -
DSP-POL -
DSP-VIP-5CL -
DSP-VIP-5TM -
DSP-VIP-5TL -
DSP-VIP-5EM -
DSP-VIP-5EL -
DSP-VIP-RTL -
DSP-VIP-RM -
DSP-VIP-RL -
WKS-1325SQH -
WKS-1270SQH -
WKS-1240SQH -
WKS-1225SQH -
WKS-1370SQAC -
WKS-1340SQAC -
WKS-1325SQAC -
WKS-1270SQAC -
WKS-1240SQAC -
WKS-1225SQAC -
WKS-1370SQ -
WKS-1340SQ -
WKS-1325SQ -
WKS-1270SQ -
WKS-1240SQ -
WKS-1225SQ -
DSP-SSR Converter -
DSP-E2CV -
HJ-114SH -
SW-ADS101 -
DSP-3SS -
DSP-SS1 -
DSP-3SS-RG -
DSP-SS1-AR -
DSP-2CT